Between-patient treatment rooms
Dental, GP, allied health, and specialist rooms get a fast disinfection cycle while staff turn over instruments.
Clinical practice already manages infection control via autoclave, single-use, and surface wipe. UV-C fills the gap between — treating waiting rooms, treatment chairs, equipment surfaces, and high-touch fixtures with hospital-grade efficacy.
UV Sterile is not a replacement for your sterilisation pathway. We supplement it — closing the gap between patients in treatment rooms, refreshing waiting areas during clinic hours, and providing rapid surface disinfection after high-risk procedures or known-exposure visits. All without disrupting clinical workflow or contaminating clean stock.
Persistent surface colonisation on chairs, lamps, and exam tables.
Highly resistant to many surface disinfectants; UV-C reduces vegetative load.
Waiting rooms concentrate respiratory exposure across patient cohorts.
Visible decontamination after blood-procedure rooms.
Dental, GP, allied health, and specialist rooms get a fast disinfection cycle while staff turn over instruments.
End-of-morning or end-of-day disinfection of chairs, magazines, reception counters, and door handles.
After known infectious exposure or high-aerosol procedures.
Overnight treatment of the entire clinic — preferred by many practices.
Treatment supports your obligations under the NHMRC Australian Guidelines for the Prevention and Control of Infection in Healthcare. We provide detailed treatment logs by room, including dwell time and treatment date — suitable for AHPRA inspections and practice accreditation visits.
At our exposure times, no. We've serviced dental practices with sensitive imaging equipment, GP clinics with monitor arrays, and allied-health rooms with no reported damage.
We prefer to treat after sharps are disposed and instruments are bagged for autoclaving. Stock cabinets can remain closed during treatment.
We work alongside — not instead of — your cleaning team. They handle visible cleaning; we add disinfection. Treatment logs are kept separate.
Yes. Call 0417 631 743 — we maintain after-hours response capacity for clinical clients.
Yes. Clinics across the Sunshine Coast, plus Brisbane and the Gold Coast on scheduled or next-day bookings — the same technician and the same unit either way. Practice groups spread across several states are usually better served by a unit at each site than by travel on every visit.
IEC 62471, the photobiological safety standard for lamps and lamp systems. The unit is rated against it and operated inside the exposure limits it publishes. Operator exposure is handled separately, under the ICNIRP guidelines for UV-C occupational exposure. The job report for each visit records the Work Health and Safety Act 2011 steps taken — risk assessment, exposure prevention and re-entry confirmation — and files alongside the room-by-room treatment log. There is more on how we operate, including what each standard covers.
They are cautious about it, and you should hear that from us rather than find it later. On UV light disinfection as a routine adjunct to terminal cleaning, the guidelines carry a weak recommendation against — the stated reason is that the effectiveness has not yet been established, not that it was tested and failed — and they say it may be considered in high-risk settings and during outbreaks once other disinfection options have been exhausted. The systematic review commissioned alongside them put it the same way: limited evidence either way. That narrow use is the one we are actually booked for. A known exposure, a room a confirmed case has been through, a treatment room that has to turn over faster than a wipe-down and its dry time allow. Where the guidelines are not cautious at all is cleaning and documentation, and that is what the room-by-room log supports: it records a treatment on top of your clean. It is not evidence of a terminal clean and we will not describe it as one.